How RareCyte designs and analytically validates its RarePlex CTC assays to pharma and CLIA standards, from antibody-clone screening and reagent titration through enumeration recovery and biomarker accuracy.

RareCyte&rsquo;s Tad George, Senior Vice President of Biology R&D, walks through how the company designs and analytically validates its RarePlex circulating tumor cell (CTC) assays to pharma and CLIA standards, with the accuracy and precision that rare-event detection demands. He follows the full end-to-end platform: nucleated cells are prepared to slides on the AccuCyte&reg; system, stained with RarePlex staining kits on manual or automated stainers, and scanned on CyteFinder&reg; instruments whose integrated machine-learning classifiers speed concordant results. Worked examples from the neuroendocrine, prostate (ARv7), PD-L1, and breast (HER2/ER) assays illustrate the three-phase development process, from assay design through production transfer to analytical validation.

In this video:

- Why RarePlex assays are built to pharma and CLIA standards emphasizing accuracy and precision, and how RareCyte covers every stage of a CTC assay from blood draw to result.

- The three-phase development process: design (assay optimization to a locked assay), transfer to manufacturing, then a regimented analytical validation of the manufactured kit.

- How per-cell mean fluorescence intensity (MFI) drives clone screening and titration, e.g. setting the synaptophysin antibody at 3 &micro;g/mL for best signal-to-background.

- Enumeration performance: 47 of 49 spiked cells recovered across nine limit-of-detection replicates (96%), at perfect sensitivity, specificity, and accuracy vs limit-of-blank.

- Clinical concordance: a customer lab&rsquo;s blinded CLIA study of roughly 50 paired prostate and breast draws tracked closely with the FDA-cleared CellSearch test.

- Biomarker validation and assay menu: MFI-threshold setting for ARv7 and PD-L1 (98% accuracy), plus developer kits adding up to two custom biomarkers to a RarePlex CTC assay.

Full transcript

Hi, my name is Tad George, Senior Vice President of Biology R&D at RareCyte. This presentation is focused on our RarePlex&reg; circulating tumor cell assays, in particular the approach that we take here at RareCyte to CTC assay design and validation.

Our RarePlex assays for CTC enumeration and biomarker expression analyses are designed for deployment by CROs and for academic centers conducting multi-center trials, and therefore assay requirements are set to pharma and CLIA standards with an emphasis on accuracy and precision. RareCyte products are used for all stages of a CTC assay, from blood draw to result. Nucleated cells from patient blood samples are processed to slides using our AccuCyte&reg; system, stained with our RarePlex staining kits using manual or automated stainers, and scanned with our CyteFinder&reg; instruments that include integrated machine learning algorithms that facilitate rapid and concordant results.

Here are a few examples of clinical CTCs found with our assays, showing our standard approach to detection of epithelial CTCs as nucleated events with CK and/or EpCAM expression that also lack CD45. The middle row shows an ARv7 positive prostate cancer cell revealed with our prostate assay. In the bottom row you can see a HER2/ER+ CTC identified using our breast cancer assay, highlighting the biomarker flexibility afforded by the RarePlex assay system.

Once we have decided to proceed with an assay, our development process is broken into three major phases: design, production transfer, and validation. Design is synonymous with assay optimization. During this phase we establish our surrogate sample controls, screen antibody clones, select the best fixation and antigen retrieval conditions, and titrate reagents, culminating in a locked assay that allows us to define quality control metrics for manufacturing and to set specifications for our subsequent validation. We then transfer the assay and QC procedures to manufacturing, who then make the staining kit lot that will be used for the subsequent validation studies.

Validation comprises a regimented set of studies that measure performance of the locked assay with an emphasis on accuracy and precision, using a mixture of spike-in surrogate samples and clinical samples. In the next few slides, I will show some example data from design and validation phases to give you an idea of the types of studies we perform and the data our system generates.

This design phase experiment for our neuroendocrine assays shows data that was used to select the model CTC controls and to select the synaptophysin antibody clone. Each graph shows synaptophysin mean fluorescence intensity obtained for a variety of spike-in cell lines with different anti-synaptophysin clones. Clone C on the right provided markedly better separation between the canonical pheochromocytoma neuroendocrine cell line PC12 and other cell lines known to be negative for synaptophysin, such as HL60. Interestingly, the prostate cancer cell line 22Rv1 was found to express high levels of synaptophysin as well. Because we have both a standard neuroendocrine assay as well as a prostate neuroendocrine assay, we selected 22Rv1 as our positive cell line control and BT474 as the negative cell line, and Clone C was chosen for synaptophysin detection.

Once we&rsquo;ve optimized fixation and antigen retrieval conditions, we perform the titration to determine the synaptophysin antibody concentration that provides the best signal-to-background performance. The left plot shows synaptophysin intensity for 22Rv1 cells in orange and BT474 cells in black, obtained using increasing anti-synaptophysin antibody concentrations in the assay. The plot at right shows the ratio of 22Rv1 synaptophysin signal to the background signal for synaptophysin found on surrounding white blood cells at each concentration. We chose the concentration that provides the maximum signal-to-background, in this case three micrograms per ml. This experiment highlights how we leverage quantitative per-cell mean fluorescence intensity data in our decision-making process, as it would be difficult to pinpoint the best concentration by qualitative assessment alone.

Representative images of 22Rv1 and BT474 spike-in samples stained with the neuroendocrine assay are shown here. The CTC in the center of each image panel is indicated by the presence of cytokeratin and/or EpCAM staining in green in the absence of CD45 staining. 22Rv1 cells exhibit cytoplasmic synaptophysin staining distribution, in contrast to the lack of apparent synaptophysin staining for BT474 cells.

The next few slides show some of the assay validation studies run after the assay design is locked and using kits produced by manufacturing. Because CTCs are extremely rare, often present in single digit numbers in a tube of blood, there&rsquo;s a premium demand on any CTC test to provide a combination of exquisite recovery, sensitivity, and specificity. To quantify enumeration performance, we analyze healthy normal donor blood without spiked in cells, which constitute limit of blank or LOB samples, as well as blood spiked with single digit numbers of model CTCs, which constitute limit of detection or LOD samples. As shown in the table at left, the assay identified 47 of the 49 spiked cells across 9 limit of detection sample replicates for a recovery of 96%. The table at the right shows perfect marks for sensitivity, specificity and accuracy using a positive test criteria of more than one CTC per sample. All the LOD samples were correctly scored positive for CTCs and all the LOB samples were correctly scored as negative for CTCs.

While we are very proud of our enumeration performance as measured with spike-in surrogate samples, we recognize it is most important to accurately detect clinical CTCs. In a study shown here performed by one of our customer labs as part of their CLIA certification study using our enumeration assay, CTCs from approximately 50 paired draws from prostate and breast cancer patients were enumerated in a blinded fashion using the RareCyte assay on the y-axis and the FDA-cleared CellSearch test on the x-axis. The comparison showed a high degree of correlation between the assays, demonstrating the RareCyte assay performs as expected for indications for which the gold standard is cleared.

The next few slides cover validation studies for biomarkers that leverage the use of MFI thresholds. For novel assays we utilize biomarker positive and biomarker negative cell lines to set an MFI threshold that is subsequently used to determine biomarker accuracy and precision. Here we show the data used for setting the ARv7 threshold for our prostate assay. Accuracy, shown with the gray line, and specificity, indicated by the orange bars, are plotted at different ARv7 MFI threshold values. Specificity is the fraction of biomarker negative cells identified as ARv7 negative, while accuracy is the fraction of correctly classified ARv7- and ARv7+ cells using a given threshold. For this assay, an MFI threshold of 100 provided maximum accuracy with a specificity well over 90%.

Here we show measurement of biomarker accuracy for our PD-L1 assay. The plot at right shows PD-L1 MFI values obtained with the assay for SW900 and APP1 cells and a dotted line to indicate the threshold. Sensitivity of 0.99, a specificity of 0.97, for an overall accuracy of 98 percent, indicating a highly reliable assay for PD-L1 detection.

Here we show precision measurements for the ARv7 prostate assay. In this study, seven replicate 22Rv1 samples were stained with the prostate assay on each of three stainer runs. Each box and whisker column represents the ARv7 MFI distribution for a single sample. The percentage of ARv7 positive cells is determined for each replicate with a threshold indicated by the dotted line. Using this approach, the repeatability coefficient of variation values ranged from 4.7 to 10.9 percent for the replicates within a run, while the inter-run intermediate precision across the three runs was 3 percent, demonstrating highly consistent detection of ARv7 expression by CTCs with the prostate assay.

Here we show detection of HER2 and ER on CTCs from breast cancer patient samples using our breast CTC assay. The plot shows HER2 versus ER MFI for individual clinical CTCs, with representative images shown at the right for color-coded points on the graph. From top to bottom: a double positive cell corresponding to the orange dot in the upper right quadrant; a HER2- but ER+ cell corresponding to the gray dot in the upper left quadrant; and a double negative cell corresponding to the dark dot in the lower left quadrant of the plot. The overall distribution reveals the heterogeneity in expression of these biomarkers across multiple CTCs in the clinical setting.

Here is a list of the staining kits available now or coming soon from RareCyte. In this brief presentation, I&rsquo;ve shared some data from all of these assays, and I want to point out that detailed assay validation reports are available from RareCyte upon request. In addition to the indication-specific assays, we also provide developer kits that allow you to add up to two additional biomarkers to a RarePlex CTC assay. Note, these kits use the same developer technology deployed by our scientists to develop our biomarker assays. RareCyte also offers assay services for the development of custom assays.

In summary, our RarePlex assay development process really incorporates a few key cornerstones. First of all, assay requirements are set to pharma and clinical standards with guidance from client industry experts. There&rsquo;s an emphasis on accuracy, precision, reproducibility, and clinical data during our validation. We leverage proprietary developer technology for sensitive biomarker detection on CTCs, and we also use quantitative imaging-based decision making during our assay design. This is all wrapped into an end-to-end CTC platform to meet your testing and research needs. Thank you very much for your time, and feel free to reach out to us if you&rsquo;re interested to learn more about our RarePlex assay process, deployment of CTC assays in your lab, or for information on our custom assay services.

For more information, please contact us at info@rarecyte.com.

Transcript reproduced from RareCyte&rsquo;s recorded presentation and lightly edited only for obvious transcription artifacts (word spacing, run-together numbers) and the accuracy of proper names and cell-line and product designations; the speaker&rsquo;s words, and every reported quantity, are otherwise verbatim. Slide titles and on-screen figures referenced by the speaker are not reproduced here. RarePlex CTC assays are for Research Use Only; CellSearch is the FDA-cleared comparator referenced in the enumeration concordance study, which was performed by a customer laboratory.

[Back to all resources](/#library)
## Related resources
[Poster](https://cdn.sanity.io/files/s3p6uqps/production/246a94d07c9a47c844784f113f57f4415bf84a5c.pdf) CyteFinder 2025
### Development of a CTC Based Assay to Characterize MAOA Expression in Metastatic Prostate Cancer
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/246a94d07c9a47c844784f113f57f4415bf84a5c.pdf) [Webinar](https://www.youtube.com/watch?v=vJ3YH4z1YKI) CyteFinder 2024
### New Discoveries in HER2 Detection: A Novel Method of Multimodal Detection of HER2 from a Single Tube of Blood
[Watch Webinar](https://www.youtube.com/watch?v=vJ3YH4z1YKI) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/360436f6c2d14d82f253816115d89e2ace4233e2.pdf) CyteFinder 2024
### Development and analytic validation of an ARv7 / PSMA dual biomarker circulating tumor cell assay
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/360436f6c2d14d82f253816115d89e2ace4233e2.pdf) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/f24e3e19abdbc04fe6d294d046d9639ecd410e6e.pdf) CyteFinder 2024
### Development and validation of an assay for the characterization of SSTR2 expression on CTCs from liquid biopsies
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/f24e3e19abdbc04fe6d294d046d9639ecd410e6e.pdf) [Publication](https://pmc.ncbi.nlm.nih.gov/articles/PMC11863877/) CyteFinder The Journal of Liquid Biopsy 2023
### Liquid biopsy kinetics and detection of ERBB2 amplification/HER2-positivity in refractory hepatocellular carcinoma
[View Publication](https://pmc.ncbi.nlm.nih.gov/articles/PMC11863877/) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/b4fe65d132e5579cb5e0a30c9bee5d7ff7f632ab.pdf) CyteFinder 2023
### Novel method for the detection and evaluation of disease biomarkers on white blood cells from liquid biopsies
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/b4fe65d132e5579cb5e0a30c9bee5d7ff7f632ab.pdf) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/51dd5a4aee911d671443d768abcfc0b4f83899e8.pdf) CyteFinder 2020
### Validation of a dual-marker ARv7/SYP assay for CTC characterization
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/51dd5a4aee911d671443d768abcfc0b4f83899e8.pdf) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/558dd9bd9ab2fa4c95bbc225309f5026bd3b7094.pdf) CyteFinder 2020
### Analytic validation of an assay to detect androgen receptor splice variant ARv7 protein expression on circulating tumor cells from prostate cancer patients
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/558dd9bd9ab2fa4c95bbc225309f5026bd3b7094.pdf) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/600f37993438d761629a40034f7702ebe3e46ee3.pdf) CyteFinder 2020
### Investigation of custom biomarkers on circulating tumor cells from clinical samples using RarePlex Developer Kits
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/600f37993438d761629a40034f7702ebe3e46ee3.pdf) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/d6eac85be7627ae4445c6583acad89fea879177d.pdf) CyteFinder 2020
### Validation of an assay to detect programmed death-ligand 1 (PD-L1) expression on circulating tumor cells
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/d6eac85be7627ae4445c6583acad89fea879177d.pdf) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/5962be5f1b2b288f2c069f7bd7b54890839f426a.pdf) CyteFinder 2019
### Custom biomarker investigation of circulating tumor cells using RarePlex® Developer Kits
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/5962be5f1b2b288f2c069f7bd7b54890839f426a.pdf) [Poster](https://cdn.sanity.io/files/s3p6uqps/production/886b7272733f331d2bd933c9cfa2bb97ce0e9542.pdf) CyteFinder 2018
### Novel multi-parameter assays for investigational phenotyping of circulating tumor cells
[Download Poster](https://cdn.sanity.io/files/s3p6uqps/production/886b7272733f331d2bd933c9cfa2bb97ce0e9542.pdf)